Complete system
YoLink FlowSmart Control Kit with Meter & Motorized Valve
Image unavailable for this option.
Description
Measure water use with the included pulse-output meter and control the included motorized shutoff valve through FlowSmart Control. Set a per-use volume or continuous-use duration limit to get an alert and start closing the valve when that limit is reached and its shutoff setting is enabled.
A YoLink hub is needed for app readings and control; sold separately.
A YoLink hub is needed for app readings and control; sold separately.
A YoLink hub is needed for app readings and control; sold separately.
A YoLink hub is needed for app readings and control; sold separately.
A YoLink hub is needed for app readings and control; sold separately.
Have a qualified installer flush the line, face the meter dial up and follow its flow arrow, with 10 pipe diameters straight upstream and 5 downstream. Do not exceed 140 psi at the meter; prevent freezing, protect controller/valve leads and keep the included AC adapter dry.
Have a qualified installer flush the line, face the meter dial up and follow its flow arrow, with 10 pipe diameters straight upstream and 5 downstream. Do not exceed 140 psi at the meter; prevent freezing, protect controller/valve leads and keep the included AC adapter dry.
Have a qualified installer flush the line, face the meter dial up and follow its flow arrow, with 10 pipe diameters straight upstream and 5 downstream. Do not exceed 140 psi at the meter; prevent freezing, protect controller/valve leads and keep the included AC adapter dry.
Have a qualified installer flush the line, face the meter dial up and follow its flow arrow, with 10 pipe diameters straight upstream and 5 downstream. Do not exceed 140 psi at the meter; prevent freezing, protect controller/valve leads and keep the included AC adapter dry. For this large YoLink meter, set Water Meter Equivalent to 1 in the app (default 1/10) for correct use readings.
Have a qualified installer flush the line, face the meter dial up and follow its flow arrow, with 10 pipe diameters straight upstream and 5 downstream. Do not exceed 140 psi at the meter; prevent freezing, protect controller/valve leads and keep the included AC adapter dry. For this large YoLink meter, set Water Meter Equivalent to 1 in the app (default 1/10) for correct use readings.
Specifications
- Nominal pipe size (meter/valve)
- 1/2 in (DN15)
- Pipe connection (meter)
- Meter body male NPS threads; use compatible male NPT couplers
- Pressure rating (meter)
- Up to 140 psi maximum system working pressure
- Power source (controller)
- 4 × non-rechargeable alkaline AA batteries or external 12 V DC adapter
- Ingress rating (controller)
- IP66 (controller body)
- Dimensions (controller)
- 143 × 81 × 30 mm (5.63 × 3.19 × 1.18 in)(L × W × D; controller body)
- Nominal pipe size (meter/valve)
- 3/4 in (DN20)
- Pipe connection (meter)
- Meter body male NPS threads; use compatible male NPT couplers
- Pressure rating (meter)
- Up to 140 psi maximum system working pressure
- Power source (controller)
- 4 × non-rechargeable alkaline AA batteries or external 12 V DC adapter
- Ingress rating (controller)
- IP66 (controller body)
- Dimensions (controller)
- 143 × 81 × 30 mm (5.63 × 3.19 × 1.18 in)(L × W × D; controller body)
- Nominal pipe size (meter/valve)
- 1 in (DN25)
- Pipe connection (meter)
- Meter body male NPS threads; use compatible male NPT couplers
- Pressure rating (meter)
- Up to 140 psi maximum system working pressure
- Power source (controller)
- 4 × non-rechargeable alkaline AA batteries or external 12 V DC adapter
- Ingress rating (controller)
- IP66 (controller body)
- Dimensions (controller)
- 143 × 81 × 30 mm (5.63 × 3.19 × 1.18 in)(L × W × D; controller body)
- Nominal pipe size (meter/valve)
- 1-1/2 in (DN40)
- Pipe connection (meter)
- Meter body male NPS threads; use compatible male NPT couplers
- Pressure rating (meter)
- Up to 140 psi maximum system working pressure
- Power source (controller)
- 4 × non-rechargeable alkaline AA batteries or external 12 V DC adapter
- Ingress rating (controller)
- IP66 (controller body)
- Dimensions (controller)
- 143 × 81 × 30 mm (5.63 × 3.19 × 1.18 in)(L × W × D; controller body)
- Nominal pipe size (meter/valve)
- 2 in (DN50)
- Pipe connection (meter)
- Meter body male NPS threads; use compatible male NPT couplers
- Pressure rating (meter)
- Up to 140 psi maximum system working pressure
- Power source (controller)
- 4 × non-rechargeable alkaline AA batteries or external 12 V DC adapter
- Ingress rating (controller)
- IP66 (controller body)
- Dimensions (controller)
- 143 × 81 × 30 mm (5.63 × 3.19 × 1.18 in)(L × W × D; controller body)
Manuals & support
Shipping, returns & warranty
Shipping
Free Shipping for Orders $50 and Up (U.S. Only)
Shipping policy ↗Returns
60-day returns from delivery. Customer-paid return shipping; condition and restocking terms apply.
Return policy ↗Warranty
Review the product warranty terms.
Warranty terms ↗